How do you protect air-supported roofs against snow and wind? In biogas installations and wastewater treatment, air-supported systems are often used, such as
double-layer membrane roofs and
gas domes. Deze worden technisch ontworpen om lokale weersomstandigheden te weerstaan.
How do you protect air-supported roofs against snow and wind? In biogas installations and wastewater treatment, air-supported systems are often used, such as double-layer membrane roofs and gas holders. These are technically designed to withstand local weather conditions.
It rarely happens that the weather is so exceptional that additional measures are needed. But when it does occur, it's good to know what to do and how to act. In this blog, a number of tips are given for these extreme conditions.
Double-layer membrane covering on biogas tank
Before we can explain how forces work on double-layer biogas roofs, it's useful to know how this roof is designed. Air is blown between both membranes with a fan. This air flows through the space between both membranes and is discharged back into the environment via a relief valve on the opposite side. This flowing air ensures refreshment of the air between the membranes. By providing the relief valve with a pre-calculated weight, a pressure between both membranes is mechanically set.
The lower membrane can move freely to react to the increased or decreased production of biogas. This is a dynamic whole that has been applied this way for decades. This system has also proven to withstand extreme weather conditions. In the standard version, it is suitable for temperatures between -30 °C and +70 °C, UV radiation, storms, snowfall, changing biogas pressures and sulfur-containing biogas. The exact design parameters are included in the static calculation belonging to the covering.
Our design is calculated for extreme wind speeds and wind pressures
Double-layer membrane coverings are made from oval/curved foil parts calculated using 3D modeling software to achieve their convex/round shape. In these 3D calculations, all extreme situations regarding deformation due to storms, biogas pressure, etc. are also calculated. For a standard roof in, for example, the Netherlands and Northern Germany, wind speeds of 22.5 to 25 m/s and a maximum wind pressure of approximately 0.74 kN/m2 are calculated. This can give extreme deformation as shown in the accompanying image. If you see this in practice, this is therefore an 'acceptable' situation!
Extremely heavy snow
When using a pressure between the membranes of 2.0 mbar, the upper membrane can carry a snow load of almost 20 kg/m2. With freshly fallen loose snow, 20 kg/m2 corresponds to approximately 10 cm of snow.[2] If this is wet snow, the weight per cm increases very quickly. With water, 20 kg/m2 is finally reached with just a 2 cm layer of water! Sticky snow is not only heavier, but also stays in place more easily and can cause the supporting air to no longer be able to lift the upper membrane, causing it to slowly sink down.
Since in the Netherlands, according to standards, a maximum of 70 kg/m2 of snow is normally calculated, both membranes can come to rest on the underlying support structure, which will sag under this weight. This sagging can be seen in the accompanying image. The 'sticking' of snow will mainly occur when the silo on which such a covering is placed is cold. (Often the case with post-storage or 'post-digesters'.)
Extreme deformation in wind with a gas dome
With gas domes, due to the large surface area that 'catches' wind, the deformation during storms can be even more extreme. This is clearly visible in the accompanying image of a gas dome with a diameter of 30.5 meters. This extreme deformation with a lateral displacement of over 3 meters is also calculated and the product is designed for this.
Additional measures for extremely heavy snow
If the expected snowfall is greater than calculated in the supplied static calculation, a number of additional measures can be taken to prevent conditions as described in the adjacent newspaper article [1] if possible:
- Keep the lower membrane filled with biogas as much as possible. (Up to maximum pressure in static calculation.) This allows the lower membrane to 'help carry'.
- If an inlet material filter is installed, check it for contamination and clean if necessary.
- Check pressure relief valve for proper operation. Watch for contamination!
- Check fan for operation and possible contamination or snow ingress.
- Keep emergency power available if necessary. Check if a backup fan is available.
- Check over-/underpressure safety for proper functioning. (Also check the antifreeze fluid!)
- In very extreme expectations, the pressure between the membranes can temporarily be increased -in consultation with the supplier-.
The above applies to both double-layer membrane covers and gas domes.
Additional measures in extremely strong wind
If wind speeds or pressures are expected higher than in the static calculation, for example during hurricane force, then all the above measures can also be taken. Most important is ensuring that supporting air pressure always remains present. So proper functioning of the ventilator is the most crucial precautionary measure here.
What if the roof collapses anyway?
If, due to extreme snow or wind, and despite any additional measures taken, an air-supported roof or gas holder has still 'collapsed', the snow must be removed from the cover with great care. With 'loose' snow, leaf blowers sometimes work well. With sticky 'wet' snow, this must be removed by hand using soft, non-sharp objects.
While removing the snow, adequate precautionary measures must be taken so that work can be carried out safely on and around the cover. Heating solely from the inside with warm air usually does not work in practice, because this requires an extreme amount of heat, and the melting snow forms 'water pockets' which, depending on the design of the substructure, can cause damage.
To prevent damage especially in extreme cases, Flexxolutions always designs the substructures of its FlexxoDomers for a minimum snow load of 70-85 kg/m2, and fits them as standard with a net over the substructure to spread extreme forces as evenly as possible.
By: Martin Nieuwmeijer, MSc Chemical Engineering. No rights can be derived from this document.
References
[1] Agrarheute: ‚Schneemassen: Biogasanlagen drohen einzustürzen'